In order to tap in to the sensor block to access boost pressure, you will need to install a 1/8″ NPT boost tube fitting.
Remove the cover and locate the plug on the wedge adapter between the exhaust manifold and the turbo. The plug can be drilled and tapped to accommodate the thermocouple (probe) 1/8″ NPT fitting.